• 570W 54V10.56A Open Frame Power Supply G0997
  • 570W 54V10.56A Open Frame Power Supply G0997
  • 570W 54V10.56A Open Frame Power Supply G0997
  • 570W 54V10.56A Open Frame Power Supply G0997
  • 570W 54V10.56A Open Frame Power Supply G0997
  • 570W 54V10.56A Open Frame Power Supply G0997

570W 54V10.56A Open Frame Power Supply G0997

Output: 54V10.56A 570W
Dimension: 190*136*38.6mm (L*W*H)
Transport Package: Box
Specification: 195*80*40 L*W*H(mm)
Trademark: WNL
Origin: China
Samples:
US$ 500/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Production Capacity
100000

Product Description

 

570W 54V10.56A Open Frame Power Supply G0997

 

Output: 54V10.56A 570W
Dimension: 190*136*38.6mm (L*W*H)

1.1Input Characteristics

Item

Parameter

Technical Requirement

Unit

Remark

1.1.1

Input

115

Vac

Nominal input.

230

Vac

1.1.2

Input Voltage Range

90 - 264

Vac

85Vac input can work. 

1.1.3

Frequency

47 - 63

Hz

Typ: 50Hz / 60Hz. 

1.1.4

Inrush Current

≤ 30

A

Vin = 115Vac, cold start, 25DegC.

≤ 60

A

Vin = 230Vac, cold start, 25DegC.

1.1.5

Nominal Operating Current

/

A

/

1.1.6

Maximum Input Current

≤ 10

A

Vin = 90Vac,max load.

1.1.7

Efficiency

≥ 87%

 

115Vac input voltage, 20% load.

≥ 90%

 

115Vac input voltage, 50% load.

≥ 87%

 

115Vac input voltage, 100% load.

≥ 89%

 

230Vac input voltage, 20% load.

≥ 92%

 

230Vac input voltage, 50% load.

≥ 89%

 

230Vac input voltage, 100% load.

1.1.8

Power Factor

≥ 0.95

 

100% load, 25DegC.

≥ 0.90

 

50% load, 25DegC.

1.2 Output Characteristics

Item

Parameter

Technical Requirement

Unit

Remark

1.2.1

Rated Output Voltage

+ 54

Vdc

 

1.2.2

Output Voltage Range

+51.3 - +56.7

Vdc

 

1.2.3

Rated Output Current

10.56

A

 

1.2.4

Minimum Output Current

0

A

 

1.2.5

Load Regulation

±5%

 

 

1.2.6

Line Regulation

±1%

 

 

1.2.7

Turn-On Delay Time

≤ 3

S

Rated input and rated load.

1.2.8

Rise Time

≤ 50

    ms

The output voltage from 10% to 90% of norminal input voltage and rated load.

1.2.9

Hold-Up Time

>=20

ms

V=100Vac, rated load.

1.2.10

Output Ripple and Noise

≤ 270

mVp-p

Apply a 0.1uF ceramic cap and 10uF E-Cap in parallel with output terminal for ripple and noise measurements, and set the oscilloscope bandwidth of 20MHz.

1.2.11

Turn-On/Off Overshoot

± 5%

 

Vin = 90 - 264Vac,25DegC.

1.2.12

Dynamic Response

Overshoot Amplitude

± 5%

Load variation from 10%-100%-10%, frequency range should be 50Hz to 10KHz with duty cycle 50%, current slope is 2.5A/us;

0%-50%-0%, frequency range should be 50Hz to 10KHz with duty cycle 50%, current slope is 2.5A/us;

±3%

25%-50%-25%, frequency range should be 50Hz to 10KHz with duty cycle 50%, current slope is 2.5A/us;

50%-75%-50%, frequency range should be 50Hz to 10KHz with duty cycle 50%, current slope is 2.5A/us.

 

570W 54V10.56A Open Frame Power Supply G0997570W 54V10.56A Open Frame Power Supply G0997
570W 54V10.56A Open Frame Power Supply G0997

 

570W 54V10.56A Open Frame Power Supply G0997

570W 54V10.56A Open Frame Power Supply G0997570W 54V10.56A Open Frame Power Supply G0997

570W 54V10.56A Open Frame Power Supply G0997

570W 54V10.56A Open Frame Power Supply G0997

 

570W 54V10.56A Open Frame Power Supply G0997570W 54V10.56A Open Frame Power Supply G0997570W 54V10.56A Open Frame Power Supply G0997

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
10000000 RMB
Management System Certification
ISO 9001, ISO 9000, ISO 14001, ISO 14000, OHSAS/ OHSMS 18001