Customization: | Available |
---|---|
Output: | 48W 12V4a |
Dimension: | 127*76*28(L*W*H) |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Electrical Characteristics:
1.1 |
Input Characteristics |
|||||||||||
NO. |
Items |
Technical Requirement |
Unit |
Remark |
||||||||
1.1.1 |
Rated Input Voltage |
100-240 |
Vac |
|
||||||||
1.1.2 |
Input Voltage Range |
90-264 |
Vac |
|
||||||||
1.1.3 |
Inrush Current |
150A |
A |
Vin=90Vac, cold start. |
||||||||
1.1.4 |
Maximum Input Current |
≤2A |
A |
Vin=90Vac. |
||||||||
1.1.5 |
Efficiency |
≥75% |
|
Input voltage 220Vac. |
||||||||
1.2 |
Output Characteristics |
|||||||||||
NO. |
Items |
Technical Requirement |
Unit |
Remark |
||||||||
1.2.1 |
Rated Output Voltage |
12 |
Vdc |
|
||||||||
1.2.2 |
Output Voltage Range |
11.4-12.6 |
Vdc |
|
||||||||
1.2.3 |
Rated Output Current |
4 |
A |
|
||||||||
1.2.4 |
Minimum Output Current |
0 |
A |
|
||||||||
1.2.5 |
Maximum Output Current |
4 |
A |
|
||||||||
1.2.6 |
Load Regulation |
±5% |
|
|
||||||||
1.2.7 |
Output Ripple and Noise |
≤120 |
mVp-p |
Made the oscilloscope with 20MHz bandwidth, output resistor side with 10uF & 104 capacitors parallel to decouple, normal temperature.
|
||||||||
1.2.8 |
Output Overshoot at Turn On and Turn Off |
±10% |
|
|
||||||||
1.2.9 |
Dynamic Response
|
Overshoot Amplitude |
±5% |
|
Variety load between 0%-50%-100%. |
|||||||
1.3 |
Protection Characteristics |
|||||||||||
NO. |
Items |
Technical Requirement |
Unit |
Remark |
||||||||
1.3.1 |
Output Overcurrent Protection |
Protection Point |
4.8-8 |
A |
Burp restart, restored automatically when malfunction removed. |
|||||||
1.3.2 |
Output Overvoltage Protection |
Protection Point |
|
|
|
|||||||
1.3.3 |
Output Short Circuit Protection |
The way of short circuit protection is burp restart, remove the short circuit fault and the module will automatically return to work. |