260-330W Dual Open Frame Power Supply G0591
Output: 260-330W
Dimension: 167.9*125*32(L*W*H)
Electrical Characteristics:
1.1 |
Input Characteristics |
NO. |
Items |
Technical Requirement |
Unit |
Remark |
1.1.1 |
Rated Input Voltage |
100-240 |
Vac |
|
1.1.2 |
Input Voltage Range |
90-264 |
Vac |
|
1.1.3 |
Frequency Range |
47-63 |
Hz |
|
1.1.4 |
Inrush Current |
≤100 |
A |
Vin=110/220Vac, cold condition. |
1.1.5 |
Maximum Input Current |
≤5 |
A |
Vin=110Vac. |
1.1.6 |
Efficiency |
≥88% |
|
Rated load @220VAC. |
1.1.7 |
Power Factor |
≥0.95 |
|
Rated load. |
1.2 |
Output Characteristics |
NO. |
Items |
Technical Requirement |
Unit |
Remark |
1.2.1 |
Rated Output Voltage |
51 |
5 |
Vdc |
|
1.2.2 |
No Load Output Voltage Variation △V |
0.2 |
0.2 |
Vdc |
|
1.2.3 |
Output Voltage Range |
50-52 |
5.0-5.4 |
Vdc |
5V Output voltage range at the customer 's request. |
1.2.4 |
Rated Output Current |
4.7 |
4 |
A |
|
1.2.5 |
Minimum Output Current |
0 |
0 |
A |
|
1.2.6 |
Maximum Capacitive Load |
6000 |
5000 |
uF |
|
1.2.7 |
Load Regulation |
±3% |
±3% |
|
|
1.2.8 |
Output Ripple and Noise |
≤400 |
≤80 |
mVp-p |
Vin=110/220Vac
Made the oscilloscope with 20MHz bandwidth,
output resistor side with 10uF & 104 capacitors parallel to decouple.
|
1.2.9 |
Turn-On Delay Time |
≤3 |
≤3 |
S |
Vin=220Vac,rated load. |
1.2.10 |
Hold-Up Time |
≥10 |
≥10 |
mS |
|
1.2.11 |
Output Overshoot at Turn On and Turn Off |
±5% |
±5% |
|
|
1.2.12 |
Dynamic Response
|
Overshoot Amplitude |
±5% |
|
Variety load between 25%-50%-25% or 50%-75%-50%. |
Recovery Time |
△t≤200 |
µS |
1.3 |
Protection Characteristics |
NO. |
Items |
Technical Requirement |
Unit |
Remark |
1.3.1 |
Input Undervoltage Protection |
65-88 |
Vac |
Re-start. |
1.3.2 |
Input Overvoltage Protection |
|
|
no |
1.3.4 |
Output Overvoltage Protection |
54-60 |
no |
Vdc |
Experimental method is open loop voltage.
Both ways may automatically remove. |
1.3.5 |
Output Overcurrent Protection |
5.5-8.5 |
5-7 |
A |
Both ways may automatically remove. |
1.3.6 |
Over Temperature Protection |
90-100 |
ºC |
|
1.3.7 |
Output Short Circuit Protection |
The way of short circuit protection is burp restart, both ways may automatically remove. |
|